Internal HI-LO Gauge
4 quick steps check internal alignment
You can check the internal alignment of your
fit-up quickly with the G.A.L. HI-LO gauge.
1. Unlock the retaining screw. Press the gauge legs
beyond the barrel.
2. Insert the legs (wires) into the root gap space or
the two pieces of pipe to be fitted. Turn the gauge
90°, being careful to apply a constant back pressure
to the barrel.
3. Hold the gauge as square as possible with the
fitting to obtain an accurate reading. Lock the
retaining screw. Reverse the 90° turn and remove the
gauge. Youre now ready to read the increment
opposite the red line.
4. When the red line aligns with the 1/32 increment
line you have a good internal alignment and fit-up.
Misalignment can be determined from the zero line
by increment markings of 1/16 inch.
|