Portable Doppler Flow Meter “Micronics” Model PF D550icon  
รหัส : MICRONICS001
ยี่ห้อ : Micronics
รุ่น : PF D550
ราคาปกติ :  240,000.00 THB      
ราคาพิเศษ :  228,000.00THB
ไฟล์เอกสาร : micronics001.pdf
รายละเอียดย่อ :
Use a PF D550 Portable Doppler Flow Meter to monitor and balance flow, or to troubleshoot flow problems in full pipes. It is ideal to evaluate performance of in-line flow meters and can be installed, calibrated and started-up in minutes. Use it for projects where a permanent flowmeter is not required or to temporarily replace installed flow transmitters.

The PF D550 ultrasonic sensor is clamped on the outside of a pipe. An acoustic pulse is reflected back to the sensor from particles or gases in the flowing liquid. The flow rate of any fluid can be measured as long as it contains air bubblers or solids. It is ideal for wastewater, slurries, sludge and most chemicals, acids, caustics and lubrication fluids. With its internal battery the PF D550 can be operated all day and then recharged overnight. For continuous use it can be powered by a supplied 110-240VAC wall plug adapter. A 300,000 point data logger is built-in.
รายละเอียดทั้งหมด :

 

General Specifications

PORTAFLOW D550 Portable Doppler Flow Meter

 

Flow Rate Range:

+/-0.03 to 12.2 m/sec (+/- 0.1 to 40 ft/sec) in most applications

 

Pipe Size:

Ultrasonic sensor mounts on any pipe from 12.5 mm to 4.5 m (1/2” to 180” ID)

 

Display:

White, backlit matrix – displays flow rate, totalizer, operating mode and calibration menu

Power Input:

Built-in NiMH battery for up to 18 hours continuous operation

External charger with 100-240 VAC 50/60 Hz input

 

Outputs:

4-20 mA (500 ohm) when AC  powered

USB for Data Log transfer by direct PC connection

 

Data Logger:

Programmable 300,000 data point capacity, time and date stamped or formatted reports including total, average, minimum, maximum and  times of occurrence

 

PC Software

‘Logger’ for Windows retrieves, displays and saves data log files

 

Electronics Operating Temperature:

-23° to 60°C

(-10° to 140°F)

 

Electronics Enclosure:

Portable, ABS enclosure

 

Carry Case:

Rated IP67 with protective molded foam insert

 

Accuracy:

2% of full scale, requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability: +/-0.25%, Linearity: +/-0.5%

 

Calibration:

Built-in 5-key programming with user-friendly calibration menu, password protected

 

Language Selection:

English, French, Spanish

 

Sensitivity:

Adjustable cut-off, Damping: adjustable

 

Approvals:

Charger is CE and UL approved. The PF D550 is not certified for use in hazardous rated locations

 

 

 

Sensor Specifications

 

 

Standard Model PSE4:

Clamp-on, single-head ultrasonic for pipes from 12.5 mm to 4.5 m (1/2” to 180” ID)

with 3.4 m (12 ft) shielded dual-coaxial cable

 

Sensor Mounting Kit:

Stainless steel pipe clamp and 150 g (5.3 oz.) silicone coupling compound

 

Operating Temperature:

-40° to 120°C (-40° to 250°F)

 

 

 

Options

 

 

Sensor Cable:

15 m (50 ft) sensor cable extension, shielded, with connectors

 

Sensor Mounting:

Extra silicone coupling compound. Additional stainless steel pipe clamps

 

 

 

Recommended for:

 

§  Sewage

§  Treated Wastewater

 

§  Aerated Water

§  Sludge and Slurries

 

§  Chemicals and Solvents

§  Viscous Liquids

 

§  Abrasives

§  Food Products

 

§  Pulp Stock

§  Acids and Caustics

 

 

 

The PF D550 is ideal to measure full pipe flow of any liquid containing gas bubbles or solids larger than 100 microns

 

and in concentrations greater than 75 ppm.

 


Quantity